Product Details:
Minimum Order Quantity | 1 Piece |
Type of Cooling Tower | Induced Draft Cooling Tower |
Cooling Capacity | Up To 20 TR |
Usage/Application | Industrial |
Shape | Dome Shaped |
Tower Material | Fiberglass Reinforced Polyester |
Voltage | 280V |
Frequency | 60Hz |
Finishing | Color Coated |
ICT (Induced Draft Counter flow Cooling Tower) Round Shaped Or Popularly Known As Bottle Type Are Designed To Cool Industrial Re-cycled Process Water From Temperature Of 50 Degrees To Temperature Of 4 Plus The Prevailing Wet Bulb Temperature Of The Region The Tower Design Incorporates Hot Water Inlet At The Bottom Collection Sump Circulated Vertically To The Mechanical Rotary Sprinkler Located Above The Fill Media. The Inlet Water Pressure Rotate The Sprinkler, Having Extended Arm Pipes With Orifices To Disperse Water Uniformly Over The Fill Media. The Fan Directly Coupled To The Motor, During Operations Takes Away The Heat By Induced Draft Mechanism. Air Is Drawn From The Lower Air In Take Area & Is Induced To Travel Through The Fill Media Thus Taking Away The Latent Heat From The Water Passing Through The Fill Media. Portion Of Water Evaporated, Removes The Heat From The Remaining Water. The Warm Moist Air Is Drawn Through The Fan Deck Is Discharged To The Atmosphere. Cold Water, Collected At The Collection Sump, Is Re-circulated To The Source.
Principal FunctionWarm Water From The Heat Source Is Circulated To The Water Distribution System. The Water Is Dispersed Uniformly Over The Wet Deck Fill By Means Of Orifice Of The Extended Arm Pipes Of The Rotary Sprinkler. Simultaneously, Air Is Drawn In Through The Air Inlet Louvers At The Base Of The Tower And Travels Upward Through The Wet Deck Fill Opposite To The Direction Of The Water Flow. A Small Portion Of The Water Is Evaporated Which Removes The Heat From The Remaining Water. The Warm Moist Air Is Drawn To The Top Of The Cooling Tower By The Fan And Discharged To The Atmosphere. The Cool Water Drains To The Basin At The Bottom Of The Tower And Is Returned To The Heat Source.
Technical FunctionThe Tower Design Incorporates Water Inlets At The Bottom Collection Sump Through Which Water Is Circulated Vertically To The Mechanical Rotary Sprinkler Located Above The Fill Media. The Inlet Water Forces The Rotary Sprinkler, Having Extended Arm Pipes With Orifices To Rotate About And Disperse Water Uniformly Over The Fill Media. The Fan Directly Coupled To The Motor Is Located On The Top And During Operations Take Away The Heat By Induced Draft Mechanism. Air Is Drawn From The Lower Air In Take Area & Is Forced To Travel Through The Fill Media Vertically. During This Process It Takes Away The Heat From The Water Passing Through The Fill Media. A Small Portion Of The Water Is Evaporated Which Removes The Heat From The Remaining Water. The Warm Moist Air Is Drawn Through The Fan Deck, By The Fan And Discharged To The Atmosphere. Cold Water Is Collected At The Collection Sump Having The Outlet Connection Through Which Cold Water Is Re-circulated To The Application.
Additional Information: